Technical Parameters:

Capacity

 5-60t

Furnace Door Type

Vertical door

Furnace Type

Stationary

Melting Rate

2-8t AI. / hour

Air Pressure

65-100KPa

Temperature Accuracy

 ±5°C

Gas Consumption Scope

52m3/t*aluminum

Highest Working Temperature

1050°C

Highest Temperature Control

1100°C



Characteristics:

Large range of low front design (2.5 m to 6.5 m), convenient to different user requirements.

Low power consumption is low, low gas consumption can be low to 52 m3 / ton * aluminum (press) of computation of natural gas.

Use of regenerative combustion system, exhaust temperature is low, about 250 degrees Celsius, to reduce the heat away from the furnace, reducing energy consumption.

Low temperature control methods: thermocouple of continuous temperature measurement, automatic regulating firepower.