Technical Parameters:
Capacity | 5-60t |
Furnace Door Type | Vertical door |
Furnace Type | Stationary |
Melting Rate | 2-8t AI. / hour |
Air Pressure | 65-100KPa |
Temperature Accuracy | ±5°C |
Gas Consumption Scope | ≥52m3/t*aluminum |
Highest Working Temperature | 1050°C |
Highest Temperature Control | 1100°C |
Characteristics:
● Large range of low front design (2.5 m to 6.5 m), convenient to different user requirements.
● Low power consumption is low, low gas consumption can be low to 52 m3 / ton * aluminum (press) of computation of natural gas.
● Use of regenerative combustion system, exhaust temperature is low, about 250 degrees Celsius, to reduce the heat away from the furnace, reducing energy consumption.
● Low temperature control methods: thermocouple of continuous temperature measurement, automatic regulating firepower.